Manager Manual for the CD72/95/15001 Page 103
Message Extra Description
Line OK whole
system
The line fault has been resolved.
Medical zone
There has been a medical alarm in this zone.
No AA user
The user has cancelled the automatic arming for this day.
NoMessage system
The dialler has reached the number of attempts at which this
message must be generated. Depending on the set-up, the dialler
may make more attempts and thus be able to report its message.
Partguard 000
The system has been partially armed via upload/download.
Partguard user
The user has partially armed the system.
Power Fail whole
system
The panel is completely without power or there was a watchdog
restart.
Raid zone
There has been a raid alarm in this zone.
RaidR remote A raid alarm has been activated using the áâáâ keys on the ‘remote’
control panel.
Reset 000
As long as a timeslot is active, it is only possible to restore an alarm
in the system. In this case this has been done via upload/download.
Reset user
As long as a timeslot is active, it is only possible to restore an alarm
in the system. In this case this has been done by the user.
REX fault remote
The system no longer has a connection with remote extension
‘remote’.
RKP fault remote
The system no longer has a connection with remote control panel
‘remote’.
Tam.CP4003 --
The zone extension CP4003 has been removed without it being
indicated in the programming.
Tamper zone
There has been a tamper alarm in this zone.
Tech. zone
There has been a technical alarm in this zone.
TPC NoAA --
Automatic arming did not take place on this day. This was done
using upload/download.
TSDelay user
The user has delayed automatic arming. This can be a set time or
the user has entered a new time.
TstFault zone
The zone was not tested or tested as faulty during the walk test.
Tst OK zone
The zone tested as correct during the walk test.
TslotReset --
There was an alarm while the system was disarmed. This alarm has
been reset by the timer.
U/D Start --
Upload/download started.
U/D End --
Upload/download finished.
Uninhibit zone
The inhibit has been removed from this zone, the next display
indicates who removed the inhibit from the zone. If
‘Upload/Download’ is displayed, this was done using
upload/download.
User user
The user has given the installer access to engineer mode.
WalkTest user
The user has carried out a walk test.
Table one: Messages in the engineer log
Other messages which can occur in the system.
Message Description
**** V6.00
The control panel is not installed
Alarm other Area.
There has been an alarm in an area other than the one for which you have
entered the code (split system)